EcoFlow

EcoFlow RIVER 2 Max

EcoFlow RIVER 2 Max stores 512 Wh and can hold a continuous 500 W load, plus X-Boost to 1,000 W for simple heaters.

Check priceOpens the manufacturer page. No affiliate link is set in links.json.

Specifications

Capacity512 Wh
Usable in Willrun math435 Wh (× 0.85)
Continuous AC output500 W
Motor surge usedNot used
Resistive boostX-Boost 1,000 W
ChemistryLiFePO4
Cycle life3,000 cycles to 80%+
Weight13.4 lb
Dimensions10.6 × 10.2 × 7.7
Outlets4 AC outlets, 500 W shared, plus USB-A, USB-C (100 W), and 12.6 V DC ports on the product spec list.
Launch priceNot verified. Current shelf prices were not copied in.
Sourcehttps://us.ecoflow.com/products/river-2-max-portable-power-station
Product spec: 512 Wh and 500 W (surge 1,000 W). The same 1,000 W is the X-Boost rating on EcoFlow's comparison table, which also lists 13.4 lb and 4 AC outlets. Willrun does not treat that 1,000 W as motor-start capacity.

Every appliance in the set

ApplianceVerdictRuntime
Danby DCR032C1WDB 3.2 cu ft compact refrigeratorRuns, surge risk17.5 hr
Danby DAR032B1SLM 3.2 cu ft compact refrigeratorRuns, surge risk14.7 hr
Danby DAR026A1BDD 2.6 cu ft compact refrigeratorRuns, surge risk15.1 hr
Danby DAR010A1BDB 1.0 cu ft compact refrigeratorRuns, surge risk15.8 hr
Samsung RT18DG6300 17.5 cu ft top-freezer refrigeratorNo run verdict11.5 hr
Whirlpool WZC3209LW 9 cu ft chest freezerNo run verdict19.0 hr
Danby DCF100A5WDB 10 cu ft chest freezerNo run verdict18.1 hr
Frigidaire FFFH20F3W 20 cu ft upright freezerNo run verdict8.0 hr
BLACK+DECKER BDM05C 5,000 Btu/h window air conditionerRuns, surge risk1.3 hr
BLACK+DECKER BD08NWES 8,000 Btu/h window air conditionerWon't run—
BLACK+DECKER BD12NWES 12,000 Btu/h window air conditionerWon't run—
GE PWJV10 10,000 Btu/h window air conditionerWon't run—
Zoeller Model 53 3/10 HP sump pump, 115 VWon't run—
ResMed AirSense 11, typical power from the user guideRuns7.8 hr
ResMed AirSense 11 AutoSet, no humidifierRuns2.6 days
ResMed AirSense 11 with HumidAir 11 and ClimateLineAir 11Runs7.9 hr
ResMed AirMini travel CPAPRuns2.9 days
LG 55QNED85 55-inch TVRuns5.7 hr
Sansui LE-32T1 32-inch TVRuns15.3 hr
Sansui LE-55V4 55-inch TVRuns6.0 hr
Samsung QN65QN90D 65-inch TVRuns3.6 hr
LG 27BA450 27-inch monitorRuns36.9 hr
Amana AMND501BW dehumidifier, about 50 pints/dayRuns, surge risk54 min
Frigidaire FHDD2233Y1 dehumidifier, about 22 pints/dayRuns, surge risk1.7 hr
Hunter 52774 44-inch ceiling fan, high speedRuns34.8 hr
Hunter 52881 44-inch ceiling fan, high speedRuns24.7 hr
Broan 688ESL bathroom fanRuns26.1 hr
Broan 744 bathroom fanRuns24.9 hr
Simply Conserve L9W-A19 LED bulbRuns2.0 days
Luminus PLYS120TW LED bulbRuns2.0 days
13-inch MacBook Air, included adapter maximumRuns7.3 hr
Lenovo IdeaPad Vibe 15AKP12, ENERGY STAR short idleRuns3.0 days
Lenovo IdeaPad Vibe 14AKP12, ENERGY STAR short idleRuns4.8 days
Apple Mac Studio (M5 Ultra), ENERGY STAR short idleRuns2.6 days
Lasko 755320 ceramic heater, highWon't run—
Lasko 755320 ceramic heater, lowRuns29 min
Panasonic NN-SU656WAWH microwave, electrical inputWon't run—
TP-Link Archer AX73 router, networked standbyRuns2.1 days
LG LCE3010 induction cooktop, 1,200 W zoneWon't run—
LG LCE3010 induction cooktop, 1,900 W zoneWon't run—

Questions

How long will the EcoFlow RIVER 2 Max run a CPAP?

Runs. At the AirSense 11 user-guide typical of 56.1 W, usable energy is 435 Wh and runtime is about 7.8 hr.

What does the 0.85 factor do?

Willrun multiplies nameplate watt-hours by 0.85 before dividing by average draw. That allowance is for inverter loss. It is not a measured efficiency for this model.

Is the surge rating safe to use for a fridge or a pump?

The extra headroom on this model is X-Boost. Willrun does not treat it as locked-rotor starting capacity.

Where do the station numbers come from?

Product spec: 512 Wh and 500 W (surge 1,000 W). The same 1,000 W is the X-Boost rating on EcoFlow's comparison table, which also lists 13.4 lb and 4 AC outlets. Willrun does not treat that 1,000 W as motor-start capacity.