BLACK+DECKER BDM05C 5,000 Btu/h window air conditioner
BLACK+DECKER BDM05C 5,000 Btu/h window air conditioner draws 347 W while on.
Published draw
| Running watts | 347.2 |
|---|---|
| Startup or peak watts | Not published |
| Average watts used for runtime | 347.2 |
| Duty cycle | None stored |
| Load type | compressor |
| Source | https://data.energystar.gov/d/5xn2-dv4h ENERGY STAR lists 5,000 Btu/h, CEER 14.4, 115 V, variable-speed compressor, and 260.4 kWh/year. Rated input is 5,000 ÷ 14.4 = 347.2 W. That matches the listed annual energy at the DOE room-AC assumption of 750 hours (347.2 × 750 ÷ 1,000 = 260.4). The 347.2 W figure is the draw while cooling at the rated condition, not a whole-year average. Startup watts are not published. |
Stations
| Station | Verdict | Runtime |
|---|---|---|
| EcoFlow RIVER 2 | Won't run | — |
| EcoFlow RIVER 2 Max | Runs, surge risk | 1.3 hr |
| EcoFlow RIVER 2 Pro | Runs, surge risk | 1.9 hr |
| EcoFlow RIVER 3 Plus | Runs, surge risk | 42 min |
| EcoFlow DELTA 2 | Runs, surge risk | 2.5 hr |
| EcoFlow DELTA 2 Max | Runs, surge risk | 5.0 hr |
| EcoFlow DELTA 3 | Runs, surge risk | 2.5 hr |
| EcoFlow DELTA 3 Plus | Runs, surge risk | 2.5 hr |
| EcoFlow DELTA Pro 3 | Runs, surge risk | 10.0 hr |
| BLUETTI AC70 | Runs, surge risk | 1.9 hr |
| BLUETTI AC180 | Runs, surge risk | 2.8 hr |
| BLUETTI AC200L | Runs, surge risk | 5.0 hr |
| Jackery Explorer 1000 v2 | Runs, surge risk | 2.6 hr |
| Jackery Explorer 1000 Plus | Runs, surge risk | 3.1 hr |
| Jackery Explorer 2000 Plus | Runs, surge risk | 5.0 hr |
| Jackery Explorer 2000 v2 | Runs, surge risk | 5.0 hr |
| Anker SOLIX C300 | Won't run | — |
| Anker SOLIX C800 | Runs, surge risk | 1.9 hr |
| Anker SOLIX C1000 | Runs, surge risk | 2.6 hr |
| Anker SOLIX F2000 (PowerHouse 767) | Runs, surge risk | 5.0 hr |
| Anker SOLIX F3800 | Runs, surge risk | 9.4 hr |
| Goal Zero Yeti 500X | Won't run | — |
| Goal Zero Yeti 1000X | Runs, surge risk | 2.4 hr |
| Goal Zero Yeti 1500X | Runs, surge risk | 3.7 hr |
Questions
What number does Willrun compare to the inverter?
Running watts of 347 W must fit under continuous output, or under a resistive boost when this load is a simple heater. Startup watts were not published.
How is runtime calculated?
Usable watt-hours (capacity × 0.85) divided by 347 W. No duty cycle is applied beyond the stored average.
Where did this come from?
ENERGY STAR lists 5,000 Btu/h, CEER 14.4, 115 V, variable-speed compressor, and 260.4 kWh/year. Rated input is 5,000 ÷ 14.4 = 347.2 W. That matches the listed annual energy at the DOE room-AC assumption of 750 hours (347.2 × 750 ÷ 1,000 = 260.4). The 347.2 W figure is the draw while cooling at the rated condition, not a whole-year average. Startup watts are not published.