Goal Zero

Goal Zero Yeti 500X

Goal Zero Yeti 500X stores 497 Wh and can hold a continuous 300 W load, with a published motor surge of 1,200 W.

Check priceOpens the manufacturer page. No affiliate link is set in links.json.

Specifications

Capacity497 Wh
Usable in Willrun math422 Wh (× 0.85)
Continuous AC output300 W
Motor surge used1,200 W
Resistive boostNone applied
ChemistryNMC
Cycle life500 cycles to 80%
Weight12.9 lb
Dimensions7.5 × 11.25 × 5.8
Outlets2× 120 V AC, 300 W (1,200 W surge) shared. USB-C PD at 60 W, USB-C at 18 W, 2 USB-A, a 12 V car port, and 6 mm ports.
Launch priceNot verified. Current shelf prices were not copied in.
Sourcehttps://goalzero.com/products/goal-zero-yeti-500x-portable-power-station
Spec list: 497 Wh, Li-ion NMC, 500 cycles to 80% at 0.2C, 12.9 lb, 2× 120 V AC at 300 W and 1,200 W surge. A shelf price on the page was not recorded as a launch price.

Answer pages

Every appliance in the set

ApplianceVerdictRuntime
Danby DCR032C1WDB 3.2 cu ft compact refrigeratorRuns, surge risk17.0 hr
Danby DAR032B1SLM 3.2 cu ft compact refrigeratorRuns, surge risk14.3 hr
Danby DAR026A1BDD 2.6 cu ft compact refrigeratorRuns, surge risk14.6 hr
Danby DAR010A1BDB 1.0 cu ft compact refrigeratorRuns, surge risk15.4 hr
Samsung RT18DG6300 17.5 cu ft top-freezer refrigeratorNo run verdict11.1 hr
Whirlpool WZC3209LW 9 cu ft chest freezerNo run verdict18.4 hr
Danby DCF100A5WDB 10 cu ft chest freezerNo run verdict17.5 hr
Frigidaire FFFH20F3W 20 cu ft upright freezerNo run verdict7.7 hr
BLACK+DECKER BDM05C 5,000 Btu/h window air conditionerWon't run—
BLACK+DECKER BD08NWES 8,000 Btu/h window air conditionerWon't run—
BLACK+DECKER BD12NWES 12,000 Btu/h window air conditionerWon't run—
GE PWJV10 10,000 Btu/h window air conditionerWon't run—
Zoeller Model 53 3/10 HP sump pump, 115 VWon't run—
ResMed AirSense 11, typical power from the user guideRuns7.5 hr
ResMed AirSense 11 AutoSet, no humidifierRuns2.5 days
ResMed AirSense 11 with HumidAir 11 and ClimateLineAir 11Runs7.7 hr
ResMed AirMini travel CPAPRuns2.8 days
LG 55QNED85 55-inch TVRuns5.5 hr
Sansui LE-32T1 32-inch TVRuns14.9 hr
Sansui LE-55V4 55-inch TVRuns5.8 hr
Samsung QN65QN90D 65-inch TVRuns3.5 hr
LG 27BA450 27-inch monitorRuns35.8 hr
Amana AMND501BW dehumidifier, about 50 pints/dayWon't run—
Frigidaire FHDD2233Y1 dehumidifier, about 22 pints/dayRuns, surge risk1.6 hr
Hunter 52774 44-inch ceiling fan, high speedRuns33.8 hr
Hunter 52881 44-inch ceiling fan, high speedRuns24.0 hr
Broan 688ESL bathroom fanRuns25.3 hr
Broan 744 bathroom fanRuns24.1 hr
Simply Conserve L9W-A19 LED bulbRuns46.9 hr
Luminus PLYS120TW LED bulbRuns46.9 hr
13-inch MacBook Air, included adapter maximumRuns7.0 hr
Lenovo IdeaPad Vibe 15AKP12, ENERGY STAR short idleRuns2.9 days
Lenovo IdeaPad Vibe 14AKP12, ENERGY STAR short idleRuns4.6 days
Apple Mac Studio (M5 Ultra), ENERGY STAR short idleRuns2.5 days
Lasko 755320 ceramic heater, highWon't run—
Lasko 755320 ceramic heater, lowWon't run—
Panasonic NN-SU656WAWH microwave, electrical inputWon't run—
TP-Link Archer AX73 router, networked standbyRuns2.0 days
LG LCE3010 induction cooktop, 1,200 W zoneWon't run—
LG LCE3010 induction cooktop, 1,900 W zoneWon't run—

Questions

How long will the Goal Zero Yeti 500X run a CPAP?

Runs. At the AirSense 11 user-guide typical of 56.1 W, usable energy is 422 Wh and runtime is about 7.5 hr.

What does the 0.85 factor do?

Willrun multiplies nameplate watt-hours by 0.85 before dividing by average draw. That allowance is for inverter loss. It is not a measured efficiency for this model.

Is the surge rating safe to use for a fridge or a pump?

This model publishes a surge of 1,200 W separately from any heater-only boost, so Willrun uses it when the appliance also publishes startup watts. If the appliance does not, the verdict stays a surge risk.

Where do the station numbers come from?

Spec list: 497 Wh, Li-ion NMC, 500 cycles to 80% at 0.2C, 12.9 lb, 2× 120 V AC at 300 W and 1,200 W surge. A shelf price on the page was not recorded as a launch price.