GE PWJV10 10,000 Btu/h window air conditioner

Portable power station on a kitchen counter charging a phone next to a coffee maker

GE PWJV10 10,000 Btu/h window air conditioner draws 625 W while on.

Published draw

Running watts625
Startup or peak wattsNot published
Average watts used for runtime625
Duty cycleNone stored
Load typecompressor
Sourcehttps://data.energystar.gov/d/5xn2-dv4h
ENERGY STAR lists model PWJV10W**# at 10,000 Btu/h, CEER 16, and 468.8 kWh/year, with a variable-speed compressor. Rated input is 10,000 ÷ 16 = 625 W. 625 × 750 ÷ 1,000 = 468.75, which rounds to the listed 468.8 kWh. Startup watts are not published.

Stations

StationVerdictRuntime
EcoFlow RIVER 2Won't run—
EcoFlow RIVER 2 MaxWon't run—
EcoFlow RIVER 2 ProRuns, surge risk1.0 hr
EcoFlow RIVER 3 PlusWon't run—
EcoFlow DELTA 2Runs, surge risk1.4 hr
EcoFlow DELTA 2 MaxRuns, surge risk2.8 hr
EcoFlow DELTA 3Runs, surge risk1.4 hr
EcoFlow DELTA 3 PlusRuns, surge risk1.4 hr
EcoFlow DELTA Pro 3Runs, surge risk5.6 hr
BLUETTI AC70Runs, surge risk1.0 hr
BLUETTI AC180Runs, surge risk1.6 hr
BLUETTI AC200LRuns, surge risk2.8 hr
Jackery Explorer 1000 v2Runs, surge risk1.5 hr
Jackery Explorer 1000 PlusRuns, surge risk1.7 hr
Jackery Explorer 2000 PlusRuns, surge risk2.8 hr
Jackery Explorer 2000 v2Runs, surge risk2.8 hr
Anker SOLIX C300Won't run—
Anker SOLIX C800Runs, surge risk1.0 hr
Anker SOLIX C1000Runs, surge risk1.4 hr
Anker SOLIX F2000 (PowerHouse 767)Runs, surge risk2.8 hr
Anker SOLIX F3800Runs, surge risk5.2 hr
Goal Zero Yeti 500XWon't run—
Goal Zero Yeti 1000XRuns, surge risk1.4 hr
Goal Zero Yeti 1500XRuns, surge risk2.1 hr

Questions

What number does Willrun compare to the inverter?

Running watts of 625 W must fit under continuous output, or under a resistive boost when this load is a simple heater. Startup watts were not published.

How is runtime calculated?

Usable watt-hours (capacity × 0.85) divided by 625 W. No duty cycle is applied beyond the stored average.

Where did this come from?

ENERGY STAR lists model PWJV10W**# at 10,000 Btu/h, CEER 16, and 468.8 kWh/year, with a variable-speed compressor. Rated input is 10,000 ÷ 16 = 625 W. 625 × 750 ÷ 1,000 = 468.75, which rounds to the listed 468.8 kWh. Startup watts are not published.