Refrigeration
Danby DCR032C1WDB 3.2 cu ft compact refrigerator
Danby DCR032C1WDB 3.2 cu ft compact refrigerator draws 66.4 W while on, and about 24.9 W after its published duty cycle.
Published draw
| Running watts | 66.4 |
|---|---|
| Startup or peak watts | Not published |
| Average watts used for runtime | 24.9 |
| Duty cycle | 0.375 |
| Load type | compressor |
| Source | https://www.danby.com/products/compact-refrigerators/dcr032c1wdb/ Danby lists 115 V, 66.4 W, and 218 kWh/year. Average draw is 218 × 1,000 ÷ 8,760 = 24.9 W. Duty cycle 0.375 is that average divided by 66.4 W, so it is an annual-average compressor fraction, not a hot-day measurement. Startup watts are not published. |
Stations
| Station | Verdict | Runtime |
|---|---|---|
| EcoFlow RIVER 2 | Runs, surge risk | 8.7 hr |
| EcoFlow RIVER 2 Max | Runs, surge risk | 17.5 hr |
| EcoFlow RIVER 2 Pro | Runs, surge risk | 26.2 hr |
| EcoFlow RIVER 3 Plus | Runs, surge risk | 9.8 hr |
| EcoFlow DELTA 2 | Runs, surge risk | 35.0 hr |
| EcoFlow DELTA 2 Max | Runs, surge risk | 2.9 days |
| EcoFlow DELTA 3 | Runs, surge risk | 35.0 hr |
| EcoFlow DELTA 3 Plus | Runs, surge risk | 35.0 hr |
| EcoFlow DELTA Pro 3 | Runs, surge risk | 5.8 days |
| BLUETTI AC70 | Runs, surge risk | 26.2 hr |
| BLUETTI AC180 | Runs, surge risk | 39.3 hr |
| BLUETTI AC200L | Runs, surge risk | 2.9 days |
| Jackery Explorer 1000 v2 | Runs, surge risk | 36.5 hr |
| Jackery Explorer 1000 Plus | Runs, surge risk | 43.2 hr |
| Jackery Explorer 2000 Plus | Runs, surge risk | 2.9 days |
| Jackery Explorer 2000 v2 | Runs, surge risk | 2.9 days |
| Anker SOLIX C300 | Runs, surge risk | 9.8 hr |
| Anker SOLIX C800 | Runs, surge risk | 26.2 hr |
| Anker SOLIX C1000 | Runs, surge risk | 36.0 hr |
| Anker SOLIX F2000 (PowerHouse 767) | Runs, surge risk | 2.9 days |
| Anker SOLIX F3800 | Runs, surge risk | 5.5 days |
| Goal Zero Yeti 500X | Runs, surge risk | 17.0 hr |
| Goal Zero Yeti 1000X | Runs, surge risk | 34.0 hr |
| Goal Zero Yeti 1500X | Runs, surge risk | 2.2 days |
Questions
What number does Willrun compare to the inverter?
Running watts of 66.4 W must fit under continuous output, or under a resistive boost when this load is a simple heater. Startup watts were not published.
How is runtime calculated?
Usable watt-hours (capacity × 0.85) divided by 24.9 W. The duty cycle is 0.375, derived from the source note, not assumed.
Where did this come from?
Danby lists 115 V, 66.4 W, and 218 kWh/year. Average draw is 218 × 1,000 ÷ 8,760 = 24.9 W. Duty cycle 0.375 is that average divided by 66.4 W, so it is an annual-average compressor fraction, not a hot-day measurement. Startup watts are not published.