Guide

BiPAP battery backup

Dark kitchen during a storm power outage, with a portable power station keeping the fridge and a lamp running

A ResMed AirCurve BiPAP uses 8 to 9 W without a humidifier and up to 66 W with a humidifier and heated tube, close to a CPAP.

Medical safety notice: Will It Run? gives general power estimates only, not medical advice. Power draw varies by model, settings, pressure, humidifier and altitude. Before relying on any battery, power station, inverter or generator for a medical device, confirm approved power sources with the device manufacturer and your doctor or equipment supplier, and test your setup before an emergency. Never change prescribed settings to extend battery life. If your therapy is life-sustaining, keep the backup your supplier provides, register with your utility's medical-needs program, and have an evacuation plan. Run generators outdoors only, at least 20 ft from windows and doors, because of carbon monoxide risk. In an emergency, call 911.

Machine and settingAverage draw8-hour nightNights on a 1,024 Wh station, ACOn DC, best caseSource
ResMed AirCurve 11 VAuto BiPAP, no humidifier8 W64 Wh4.713.6ResMed
ResMed AirCurve 10 VAuto BiPAP, no humidifier9 W72 Wh4.512.1ResMed
ResMed AirCurve 10 VAuto BiPAP with HumidAir humidifier23 W184 Wh2.9—ResMed
ResMed AirCurve 11 VAuto BiPAP with HumidAir humidifier34 W272 Wh2.23.2ResMed
ResMed AirCurve 10 VAuto BiPAP with HumidAir and heated tube41 W328 Wh1.9—ResMed
ResMed AirCurve 11 VAuto BiPAP with HumidAir and heated tube66 W528 Wh1.31.6ResMed

AC nights = 1,024 Wh × 0.85 usable ÷ ((watts + about 15 W inverter draw) × 8 hr). DC nights = 1,024 Wh × 0.85 ÷ (watts × 8 hr), a best case with the maker's DC converter (ResMed Air11, Air10 or AirMini) in a 12 V car port; — means DC isn't modeled for that setting (ResMed's AirSense 10 guide says humidity off on an external battery, and Philips publishes no DC figure). ResMed figures are lab measurements from ResMed's published power table; the Philips row is the 80 W power-supply ceiling, a worst case. The 15 W is the inverter's own draw: BLUETTI counts about 15 W of self-consumption in its AC180 runtime formula, and an owner test measured about 17.5 W on a DELTA 3 Plus; larger stations can idle higher. Method, DC converter limits and picks: CPAP power station guide. The RIVER 2, RIVER 3 Plus and SOLIX C300 DC figures use their 12 V car outputs (EcoFlow RIVER 2 manual: 100 W max; RIVER 3 Plus specs: 126 W max; Anker C300 guide: 12 V 10 A). The DELTA Pro 3 has 12 V Anderson and DC5521 outputs but no car socket, so it stays AC-only here.

Nights on each station (AirCurve 11 VAuto)

StationCapacityNo humidifier (AC)Humidifier (AC)Humidifier + heated tube (AC)No humidifier, DC best casePrice
EcoFlow RIVER 2256 Wh1.20.60.33.4Amazon
EcoFlow RIVER 3 Plus286 Wh1.30.60.43.8Amazon
Anker SOLIX C300288 Wh1.30.60.43.8Amazon
Goal Zero Yeti 500X497 Wh2.31.10.76.6Amazon
EcoFlow RIVER 2 Max512 Wh2.41.10.76.8Amazon
EcoFlow RIVER 2 Pro768 Wh3.51.71.010.2Amazon
BLUETTI AC70768 Wh3.51.71.010.2Amazon
Anker SOLIX C800768 Wh3.51.71.010.2Amazon
Goal Zero Yeti 1000X997 Wh4.62.21.313.2Amazon
EcoFlow DELTA 21,024 Wh4.72.21.313.6Amazon
EcoFlow DELTA 31,024 Wh4.72.21.313.6Amazon
EcoFlow DELTA 3 Plus1,024 Wh4.72.21.313.6Amazon
Anker SOLIX C10001,056 Wh4.92.31.414.0Amazon
Jackery Explorer 1000 v21,070 Wh4.92.31.414.2Amazon
BLUETTI AC1801,152 Wh5.32.51.515.3Amazon
Jackery Explorer 1000 Plus1,264.64 Wh5.82.71.716.8Amazon
Goal Zero Yeti 1500X1,516 Wh7.03.32.020.1Amazon
Jackery Explorer 2000 v22,042 Wh9.44.42.727.1Amazon
Jackery Explorer 2000 Plus2,042.8 Wh9.44.42.727.1Amazon
EcoFlow DELTA 2 Max2,048 Wh9.54.42.727.2Amazon
BLUETTI AC200L2,048 Wh9.54.42.727.2Amazon
Anker SOLIX F2000 (PowerHouse 767)2,048 Wh9.54.42.727.2Amazon
Anker SOLIX F38003,840 Wh8.55.53.851.0Amazon
EcoFlow DELTA Pro 34,096 Wh18.98.95.4—Amazon

Anker SOLIX F3800 row: nights use about 40 W of idle draw instead of 15 W, because Anker's FAQ for the F3800 Plus lists about 40 W with AC on and nothing connected (Anker). At CPAP loads that cuts its nights by roughly a third to a half; see the F3800 idle table. The F3800 DC column uses its 12 V ⎓ 10 A car charger output (Anker US user guide), which skips the inverter.

Nights of 8 hours. AC = nameplate Wh × 0.85 ÷ (average draw + about 15 W inverter draw). DC = nameplate Wh × 0.85 ÷ average draw, a best case with ResMed's Air11 DC converter in the 12 V car port; — means no car port is listed in the maker specs we checked. As an Amazon Associate we earn from qualifying purchases. The 15 W is the inverter's own draw: BLUETTI counts about 15 W of self-consumption in its AC180 runtime formula, and an owner test measured about 17.5 W on a DELTA 3 Plus; larger stations can idle higher. Method, DC converter limits and picks: CPAP power station guide.

Philips BiPAP models are not listed because Philips does not publish a typical power draw.

More CPAP guides

Questions

How long will a power station run a BiPAP?

On AC, divide 85% of the station's watt-hours by the average draw in the table plus about 15 W for the station's inverter. On DC with ResMed's converter, divide by the average draw alone, a best case.

On home oxygen? Power station for an oxygen concentrator has maker wattages, hours by station and a backup-cylinder plan.