ResMed AirCurve 10 VAuto BiPAP, no humidifier draws 9 W while on, and about 9 W after its published duty cycle.

Medical safety notice: Will It Run? gives general power estimates only, not medical advice. Power draw varies by model, settings, pressure, humidifier and altitude. Before relying on any battery, power station, inverter or generator for a medical device, confirm approved power sources with the device manufacturer and your doctor or equipment supplier, and test your setup before an emergency. Never change prescribed settings to extend battery life. If your therapy is life-sustaining, keep the backup your supplier provides, register with your utility's medical-needs program, and have an evacuation plan. Run generators outdoors only, at least 20 ft from windows and doors, because of carbon monoxide risk. In an emergency, call 911.

An 8-hour night uses about 72 Wh. Compare every CPAP and BiPAP setting on the CPAP hub.

Published draw

Running watts9
Startup or peak wattsNot published
Average watts used for runtime9
Duty cycle1
Load typeelectronics
Sourcehttps://www.resmed-healthcare.de/wp-content/uploads/2025/10/1018528r11_Uebers_Stromverbrauch-Geraete_RDE_PDF-1.pdf
ResMed's therapy-device power table (ResMed Deutschland, Art.-Nr. 1018528/11) lists AirCurve 10 VAuto at 9 Wh during operation. Energy per hour equals average watts, so the average draw is 9 W. ResMed notes the values were measured in a lab and that a local meter can differ.

Stations

StationVerdictRuntime on ACOn DC, best case
EcoFlow RIVER 2Runs9.1 hr24.2 hr
EcoFlow RIVER 2 MaxRuns18.1 hr2.0 days
EcoFlow RIVER 2 ProRuns27.2 hr3.0 days
EcoFlow RIVER 3 PlusRuns10.1 hr27.0 hr
EcoFlow DELTA 2Runs36.3 hr4.0 days
EcoFlow DELTA 2 MaxRuns3.0 days8.1 days
EcoFlow DELTA 3Runs36.3 hr4.0 days
EcoFlow DELTA 3 PlusRuns36.3 hr4.0 days
EcoFlow DELTA Pro 3Runs6.0 days—
BLUETTI AC70Runs27.2 hr3.0 days
BLUETTI AC180Runs40.8 hr4.5 days
BLUETTI AC200LRuns3.0 days8.1 days
Jackery Explorer 1000 v2Runs37.9 hr4.2 days
Jackery Explorer 1000 PlusRuns44.8 hr5.0 days
Jackery Explorer 2000 PlusRuns3.0 days8.0 days
Jackery Explorer 2000 v2Runs3.0 days8.0 days
Anker SOLIX C300Runs10.2 hr27.2 hr
Anker SOLIX C800Runs27.2 hr3.0 days
Anker SOLIX C1000Runs37.4 hr4.2 days
Anker SOLIX F2000 (PowerHouse 767)Runs3.0 days8.1 days
Anker SOLIX F3800Runs2.8 days15.1 days
Goal Zero Yeti 500XRuns17.6 hr46.9 hr
Goal Zero Yeti 1000XRuns35.3 hr3.9 days
Goal Zero Yeti 1500XRuns2.2 days6.0 days

Anker SOLIX F3800 row: uses about 40 W of idle draw instead of 15 W, because Anker's FAQ for the F3800 Plus lists about 40 W with AC on and nothing connected (Anker; F3800 idle table). The F3800 DC column uses its 12 V ⎓ 10 A car charger output (Anker US user guide), which skips the inverter. The RIVER 2, RIVER 3 Plus and SOLIX C300 DC figures use their 12 V car outputs (EcoFlow RIVER 2 manual: 100 W max; RIVER 3 Plus specs: 126 W max; Anker C300 guide: 12 V 10 A). The DELTA Pro 3 has 12 V Anderson and DC5521 outputs but no car socket, so it stays AC-only here.

How AC runtime is figured: usable Wh (nameplate × 0.85) ÷ (CPAP watts + about 15 W). The 15 W is the inverter's own draw just to stay on: BLUETTI counts about 15 W of self-consumption in its AC180 runtime formula, and an owner test measured about 17.5 W idle on a DELTA 3 Plus. Larger stations can idle higher, so test your own setup before you rely on it. DC figures skip the inverter and are a best case. Method and DC converter limits: CPAP power station guide. — means no DC figure: no 12 V car port is listed for that station in the maker specs we checked.

Shop power stations on AmazonAs an Amazon Associate we earn from qualifying purchases.

Questions

What number does Willrun compare to the inverter?

Running watts of 9 W must fit under continuous output. Startup watts were not published.

How is runtime calculated?

On AC: usable watt-hours (capacity × 0.85) divided by (9 W + about 15 W of inverter draw). On DC with the maker's converter there is no inverter, so the best case divides by 9 W alone.

Where did this come from?

ResMed's therapy-device power table (ResMed Deutschland, Art.-Nr. 1018528/11) lists AirCurve 10 VAuto at 9 Wh during operation. Energy per hour equals average watts, so the average draw is 9 W. ResMed notes the values were measured in a lab and that a local meter can differ.