Answer
Can the WEN DF1100T run Lasko 755320 ceramic heater, high?
Runs
Runs. Running draw 1,500 W fits within 8,300 running watts, and published startup 1,500 W fits within 11,000 starting watts.
Check priceOpens the manufacturer page. No affiliate link is set in links.json.
The comparison
| WEN DF1100T | Lasko 755320 ceramic heater, high | |
|---|---|---|
| Running watts | 8,300 W | 1,500 W |
| Starting / surge watts | 11,000 W | 1,500 W |
| Type | open-frame, Dual fuel (gasoline/propane) | Heat |
| Published runtime | 8.5 hr at 50% load on gasoline, 3 hr on a 20-lb propane tank | |
| Sources | Generator source | Appliance source |
Questions
Can the WEN DF1100T run Lasko 755320 ceramic heater, high?
Runs. Running draw 1,500 W fits within 8,300 running watts, and published startup 1,500 W fits within 11,000 starting watts.
What watts were compared?
Generator: 8,300 running W and 11,000 starting W on gasoline. Appliance: 1,500 W running, 1,500 W startup.
How long will it run?
Fuel runtime depends on total load. Published runtime: 8.5 hr at 50% load on gasoline, 3 hr on a 20-lb propane tank.
Where did the numbers come from?
WEN product page and manual: gasoline 11000 surge / 8300 running; propane 9500 / 7500; 4 GFCI 5-20R, L5-30R, 14-50R, 12V DC; 6.6 gal; 8.5 hr gas at 50%, 3 hr propane (20 lb). No L14-30R: a 30A 240V inlet needs a 14-50P to L14-30R adapter cord, which Willrun does not assume. Lasko lists 120 V, current 7.5 A to 12.5 A, and energy output 900 W to 1,500 W. High is 1,500 W. A resistive element does not have a separate motor surge, so surge is set equal to the high setting. The thermostat cycles in real rooms; this entry assumes the high element is on.
Safety first
- Run a generator outdoors only, at least 20 feet from the house, with the exhaust pointed away from doors, windows and vents. Never in a garage, basement, shed or crawlspace, even with the door open.
- Carbon monoxide is odorless and can kill in minutes. Keep battery CO alarms working inside the home.
- Never backfeed a house by plugging a generator into a wall outlet or dryer receptacle. It can energize utility lines and kill a lineworker or a neighbor.
- Connecting to home wiring requires a transfer switch or a listed breaker interlock with a power inlet box, installed by a licensed electrician and permitted where your jurisdiction requires it.