Answer

Can the WEN DF1100T run BLACK+DECKER BDM05C 5,000 Btu/h window air conditioner?

Runs

Runs. Running draw 347 W fits within 8,300 running watts. Startup watts were not published; 11,000 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.

Check priceOpens the manufacturer page. No affiliate link is set in links.json.

The comparison

WEN DF1100TBLACK+DECKER BDM05C 5,000 Btu/h window air conditioner
Running watts8,300 W347 W
Starting / surge watts11,000 WNot published
Typeopen-frame, Dual fuel (gasoline/propane)Cooling
Published runtime8.5 hr at 50% load on gasoline, 3 hr on a 20-lb propane tank
SourcesGenerator sourceAppliance source

Questions

Can the WEN DF1100T run BLACK+DECKER BDM05C 5,000 Btu/h window air conditioner?

Runs. Running draw 347 W fits within 8,300 running watts. Startup watts were not published; 11,000 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.

What watts were compared?

Generator: 8,300 running W and 11,000 starting W on gasoline. Appliance: 347 W running, startup not published.

How long will it run?

Fuel runtime depends on total load. Published runtime: 8.5 hr at 50% load on gasoline, 3 hr on a 20-lb propane tank.

Where did the numbers come from?

WEN product page and manual: gasoline 11000 surge / 8300 running; propane 9500 / 7500; 4 GFCI 5-20R, L5-30R, 14-50R, 12V DC; 6.6 gal; 8.5 hr gas at 50%, 3 hr propane (20 lb). No L14-30R: a 30A 240V inlet needs a 14-50P to L14-30R adapter cord, which Willrun does not assume. ENERGY STAR lists 5,000 Btu/h, CEER 14.4, 115 V, variable-speed compressor, and 260.4 kWh/year. Rated input is 5,000 ÷ 14.4 = 347.2 W. That matches the listed annual energy at the DOE room-AC assumption of 750 hours (347.2 × 750 ÷ 1,000 = 260.4). The 347.2 W figure is the draw while cooling at the rated condition, not a whole-year average. Startup watts are not published.