Answer

Can the Westinghouse WGen9500DF run Amana AMND501BW dehumidifier, about 50 pints/day?

Runs

Runs. Running draw 485 W fits within 9,500 running watts. Startup watts were not published; 12,500 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.

Check priceOpens the manufacturer page. No affiliate link is set in links.json.

The comparison

Westinghouse WGen9500DFAmana AMND501BW dehumidifier, about 50 pints/day
Running watts9,500 W485 W
Starting / surge watts12,500 WNot published
Typeopen-frame, Dual fuel (gasoline/propane)Cooling
Published runtime12 hr at 25% load on gasoline, 7 hr at 50% on propane
SourcesGenerator sourceAppliance source

Questions

Can the Westinghouse WGen9500DF run Amana AMND501BW dehumidifier, about 50 pints/day?

Runs. Running draw 485 W fits within 9,500 running watts. Startup watts were not published; 12,500 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.

What watts were compared?

Generator: 9,500 running W and 12,500 starting W on gasoline. Appliance: 485 W running, startup not published.

How long will it run?

Fuel runtime depends on total load. Published runtime: 12 hr at 25% load on gasoline, 7 hr at 50% on propane.

Where did the numbers come from?

Westinghouse spec table: gas 12500 peak / 9500 running; propane 11200 / 8500; L14-30R and 14-50R; 6.6 gal; 12 hr at 25% gas, 7 hr at 50% propane; 74 dBA; 211 lb; THD under 23%. ENERGY STAR lists 49.43 pints/day, integrated energy factor 2.01 L/kWh, and 520 kWh/year. Operating draw at the rated test condition is (49.43 × 0.473176 L/pint ÷ 24 h) ÷ 2.01 L/kWh × 1,000 = 485 W. That is the draw while it is removing water at the rated rate, not a whole-year average. Startup watts are not published.

Safety first

More on the Westinghouse WGen9500DF · More on this appliance