Answer
Can the Westinghouse iGen4500DFc run ResMed AirSense 11, typical power from the user guide?
Runs
Runs. Running draw 56 W fits within 3,700 running watts, and published startup 73 W fits within 4,500 starting watts.
Check priceOpens the manufacturer page. No affiliate link is set in links.json.
The comparison
| Westinghouse iGen4500DFc | ResMed AirSense 11, typical power from the user guide | |
|---|---|---|
| Running watts | 3,700 W | 56 W |
| Starting / surge watts | 4,500 W | 73 W |
| Type | inverter, Dual fuel (gasoline/propane) | Medical |
| Published runtime | 18 hr at 25% load on gasoline, 22 hr at 25% on propane | |
| Sources | Generator source | Appliance source |
Questions
Can the Westinghouse iGen4500DFc run ResMed AirSense 11, typical power from the user guide?
Runs. Running draw 56 W fits within 3,700 running watts, and published startup 73 W fits within 4,500 starting watts.
What watts were compared?
Generator: 3,700 running W and 4,500 starting W on gasoline. Appliance: 56 W running, 73 W startup.
How long will it run?
Fuel runtime depends on total load. Published runtime: 18 hr at 25% load on gasoline, 22 hr at 25% on propane.
Where did the numbers come from?
Westinghouse spec sheet and manual: gas 4500 peak / 3700 running; propane 4050 / 3330; 5-20R duplex, TT-30R, 2 USB; 3.4 gal; 18 hr gas / 22 hr propane at 25%; 52 dBA; 105.8 lb dry; CO sensor. Americas user guide, 65 W power supply section: typical power consumption 56.1 W (111.5 VA) and peak power consumption 73.2 W (137.6 VA). This is the published system figure, not the lower no-humidifier row on ResMed's separate therapy-power sheet.
Safety first
- Run a generator outdoors only, at least 20 feet from the house, with the exhaust pointed away from doors, windows and vents. Never in a garage, basement, shed or crawlspace, even with the door open.
- Carbon monoxide is odorless and can kill in minutes. Keep battery CO alarms working inside the home.
- Never backfeed a house by plugging a generator into a wall outlet or dryer receptacle. It can energize utility lines and kill a lineworker or a neighbor.
- Connecting to home wiring requires a transfer switch or a listed breaker interlock with a power inlet box, installed by a licensed electrician and permitted where your jurisdiction requires it.
More on the Westinghouse iGen4500DFc · More on this appliance