Answer

Can the Westinghouse iGen2200 run Zoeller Model 53 3/10 HP sump pump, 115 V?

Runs, surge risk

Runs, surge risk. Running draw 1,116 W fits within 1,800 running watts, but startup watts were not published and 2,200 starting watts is less than 3× the running draw.

Check priceOpens the manufacturer page. No affiliate link is set in links.json.

The comparison

Westinghouse iGen2200Zoeller Model 53 3/10 HP sump pump, 115 V
Running watts1,800 W1,116 W
Starting / surge watts2,200 WNot published
Typeinverter, GasolinePumps
Published runtimeUp to 12 hr at 25% load
SourcesGenerator sourceAppliance source

Questions

Can the Westinghouse iGen2200 run Zoeller Model 53 3/10 HP sump pump, 115 V?

Runs, surge risk. Running draw 1,116 W fits within 1,800 running watts, but startup watts were not published and 2,200 starting watts is less than 3× the running draw.

What watts were compared?

Generator: 1,800 running W and 2,200 starting W on gasoline. Appliance: 1,116 W running, startup not published.

How long will it run?

Fuel runtime depends on total load. Published runtime: Up to 12 hr at 25% load.

Where did the numbers come from?

Westinghouse product page: 2200 peak / 1800 running; 1.14 gal; up to 12 hr at 25%; 46.3 lb; duplex 5-20R and 2 USB. Older spec sheets list 10 hr at 25%. Zoeller lists the Model 53 at 3/10 HP, 115 V or 230 V, and 4.8–9.7 A. The 115 V automatic model in Zoeller's 50-series technical table is 9.7 A. Running watts used here are 9.7 × 115 = 1,115.5 W. Startup amps are not published. How often the float runs is site-specific, so no duty cycle is stored.

Safety first

More on the Westinghouse iGen2200 · More on this appliance