Answer

Can the Honda EU3000iS run Panasonic NN-SU656WAWH microwave, electrical input?

Runs

Runs. Running draw 1,500 W fits within 2,800 running watts and this is not a motor-start load.

Check priceOpens the manufacturer page. No affiliate link is set in links.json.

The comparison

Honda EU3000iSPanasonic NN-SU656WAWH microwave, electrical input
Running watts2,800 W1,500 W
Starting / surge watts3,000 WNot published
Typeinverter, GasolineKitchen
Published runtime6.9 hr at rated load, 19.6 hr at 1/4 load
SourcesGenerator sourceAppliance source

Questions

Can the Honda EU3000iS run Panasonic NN-SU656WAWH microwave, electrical input?

Runs. Running draw 1,500 W fits within 2,800 running watts and this is not a motor-start load.

What watts were compared?

Generator: 2,800 running W and 3,000 starting W on gasoline. Appliance: 1,500 W running, startup not published.

How long will it run?

Fuel runtime depends on total load. Published runtime: 6.9 hr at rated load, 19.6 hr at 1/4 load.

Where did the numbers come from?

Honda spec table: 120V 3000W max (25A), 2800W rated (23.3A); 20A duplex and 30A 125V locking receptacle; 3.4 gal; 6.9 hr rated / 19.6 hr 1/4 load; 57/50 dB(A); 130.7 lb dry. The 30A outlet is an L5-30R, not a TT-30R. Panasonic lists power supply 120 V / 60 Hz, microwave output 1,100 W, and microwave power consumption 1,500 W. The station has to supply the 1,500 W input, not the 1,100 W cooking output. A separate startup surge is not published. X-Boost and Power Lifting are not applied, because those modes are described for simple heating loads and a microwave is an electronic supply.

Safety first

More on the Honda EU3000iS · More on this appliance