Answer

Can the Honda EU3000iS run Danby DAR032B1SLM 3.2 cu ft compact refrigerator?

Runs

Runs. Running draw 150 W fits within 2,800 running watts. Startup watts were not published; 3,000 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.

Check priceOpens the manufacturer page. No affiliate link is set in links.json.

The comparison

Honda EU3000iSDanby DAR032B1SLM 3.2 cu ft compact refrigerator
Running watts2,800 W150 W
Starting / surge watts3,000 WNot published
Typeinverter, GasolineRefrigeration
Published runtime6.9 hr at rated load, 19.6 hr at 1/4 load
SourcesGenerator sourceAppliance source

Questions

Can the Honda EU3000iS run Danby DAR032B1SLM 3.2 cu ft compact refrigerator?

Runs. Running draw 150 W fits within 2,800 running watts. Startup watts were not published; 3,000 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.

What watts were compared?

Generator: 2,800 running W and 3,000 starting W on gasoline. Appliance: 150 W running, startup not published.

How long will it run?

Fuel runtime depends on total load. Published runtime: 6.9 hr at rated load, 19.6 hr at 1/4 load.

Where did the numbers come from?

Honda spec table: 120V 3000W max (25A), 2800W rated (23.3A); 20A duplex and 30A 125V locking receptacle; 3.4 gal; 6.9 hr rated / 19.6 hr 1/4 load; 57/50 dB(A); 130.7 lb dry. The 30A outlet is an L5-30R, not a TT-30R. Danby lists 115 V, 150 W, and 259 kWh/year. Average draw is 29.6 W. Duty cycle 0.197 is the annual average implied by those two figures. Startup watts are not published.

Safety first

More on the Honda EU3000iS · More on this appliance