Can the Generac iQ3500 COsense run BLACK+DECKER BDM05C 5,000 Btu/h window air conditioner?

Runs

Runs. Running draw 347 W fits within 3,000 running watts. Startup watts were not published; 3,500 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.

Check priceOpens the manufacturer page. No affiliate link is set in links.json.

The comparison

Generac iQ3500 COsenseBLACK+DECKER BDM05C 5,000 Btu/h window air conditioner
Running watts3,000 W347 W
Starting / surge watts3,500 WNot published
Typeinverter, GasolineCooling
Published runtime14.1 hr at 25% load, 8.9 hr at 50% load
SourcesGenerator sourceAppliance source

Questions

Can the Generac iQ3500 COsense run BLACK+DECKER BDM05C 5,000 Btu/h window air conditioner?

Runs. Running draw 347 W fits within 3,000 running watts. Startup watts were not published; 3,500 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.

What watts were compared?

Generator: 3,000 running W and 3,500 starting W on gasoline. Appliance: 347 W running, startup not published.

How long will it run?

Fuel runtime depends on total load. Published runtime: 14.1 hr at 25% load, 8.9 hr at 50% load.

Where did the numbers come from?

Generac spec sheet: 3000 W running, 3500 W starting; L5-30R (not TT-30R); 14.1 hr at 25%, 8.9 hr at 50%; 109.1 lb. ENERGY STAR lists 5,000 Btu/h, CEER 14.4, 115 V, variable-speed compressor, and 260.4 kWh/year. Rated input is 5,000 ÷ 14.4 = 347.2 W. That matches the listed annual energy at the DOE room-AC assumption of 750 hours (347.2 × 750 ÷ 1,000 = 260.4). The 347.2 W figure is the draw while cooling at the rated condition, not a whole-year average. Startup watts are not published.

Safety first

More on the Generac iQ3500 COsense · More on this appliance