Answer

Can the Generac GP8000E COsense run Zoeller Model 53 3/10 HP sump pump, 115 V?

Runs

Runs. Running draw 1,116 W fits within 8,000 running watts. Startup watts were not published; 10,000 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.

Check priceOpens the manufacturer page. No affiliate link is set in links.json.

The comparison

Generac GP8000E COsenseZoeller Model 53 3/10 HP sump pump, 115 V
Running watts8,000 W1,116 W
Starting / surge watts10,000 WNot published
Typeopen-frame, GasolinePumps
Published runtime15 hr at 25% load, 10 hr at 50% load
SourcesGenerator sourceAppliance source

Questions

Can the Generac GP8000E COsense run Zoeller Model 53 3/10 HP sump pump, 115 V?

Runs. Running draw 1,116 W fits within 8,000 running watts. Startup watts were not published; 10,000 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.

What watts were compared?

Generator: 8,000 running W and 10,000 starting W on gasoline. Appliance: 1,116 W running, startup not published.

How long will it run?

Fuel runtime depends on total load. Published runtime: 15 hr at 25% load, 10 hr at 50% load.

Where did the numbers come from?

Generac spec sheet: 8000 W running, 10000 W starting; L14-30R with 2-pole 30A breaker; 15 hr at 25%, 10 hr at 50%; COsense shutdown. Zoeller lists the Model 53 at 3/10 HP, 115 V or 230 V, and 4.8–9.7 A. The 115 V automatic model in Zoeller's 50-series technical table is 9.7 A. Running watts used here are 9.7 × 115 = 1,115.5 W. Startup amps are not published. How often the float runs is site-specific, so no duty cycle is stored.

Safety first

More on the Generac GP8000E COsense · More on this appliance