Answer

Can the Generac GP8000E COsense run GE PWJV10 10,000 Btu/h window air conditioner?

Runs

Runs. Running draw 625 W fits within 8,000 running watts. Startup watts were not published; 10,000 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.

Check priceOpens the manufacturer page. No affiliate link is set in links.json.

The comparison

Generac GP8000E COsenseGE PWJV10 10,000 Btu/h window air conditioner
Running watts8,000 W625 W
Starting / surge watts10,000 WNot published
Typeopen-frame, GasolineCooling
Published runtime15 hr at 25% load, 10 hr at 50% load
SourcesGenerator sourceAppliance source

Questions

Can the Generac GP8000E COsense run GE PWJV10 10,000 Btu/h window air conditioner?

Runs. Running draw 625 W fits within 8,000 running watts. Startup watts were not published; 10,000 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.

What watts were compared?

Generator: 8,000 running W and 10,000 starting W on gasoline. Appliance: 625 W running, startup not published.

How long will it run?

Fuel runtime depends on total load. Published runtime: 15 hr at 25% load, 10 hr at 50% load.

Where did the numbers come from?

Generac spec sheet: 8000 W running, 10000 W starting; L14-30R with 2-pole 30A breaker; 15 hr at 25%, 10 hr at 50%; COsense shutdown. ENERGY STAR lists model PWJV10W**# at 10,000 Btu/h, CEER 16, and 468.8 kWh/year, with a variable-speed compressor. Rated input is 10,000 ÷ 16 = 625 W. 625 × 750 ÷ 1,000 = 468.75, which rounds to the listed 468.8 kWh. Startup watts are not published.

Safety first

More on the Generac GP8000E COsense · More on this appliance