Runs. Running draw 625 W fits within 10,500 running watts. Startup watts were not published; 13,000 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.
Check priceOpens the manufacturer page. No affiliate link is set in links.json.
The comparison
| DuroMax XP13000EH | GE PWJV10 10,000 Btu/h window air conditioner | |
|---|---|---|
| Running watts | 10,500 W | 625 W |
| Starting / surge watts | 13,000 W | Not published |
| Type | open-frame, Dual fuel (gasoline/propane) | Cooling |
| Published runtime | 8.5 hr at 50% load on gasoline, 6.5 hr at 50% on propane | |
| Sources | Generator source | Appliance source |
Questions
Can the DuroMax XP13000EH run GE PWJV10 10,000 Btu/h window air conditioner?
Runs. Running draw 625 W fits within 10,500 running watts. Startup watts were not published; 13,000 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.
What watts were compared?
Generator: 10,500 running W and 13,000 starting W on gasoline. Appliance: 625 W running, startup not published.
How long will it run?
Fuel runtime depends on total load. Published runtime: 8.5 hr at 50% load on gasoline, 6.5 hr at 50% on propane.
Where did the numbers come from?
DuroMax spec sheet: gasoline 13000 starting / 10500 running; propane 12350 / 9975; 120/240V 30A twist-lock and 14-50R; 8.5 hr gas / 6.5 hr propane at 50%. ENERGY STAR lists model PWJV10W**# at 10,000 Btu/h, CEER 16, and 468.8 kWh/year, with a variable-speed compressor. Rated input is 10,000 ÷ 16 = 625 W. 625 × 750 ÷ 1,000 = 468.75, which rounds to the listed 468.8 kWh. Startup watts are not published.
Safety first
- Run a generator outdoors only, at least 20 feet from the house, with the exhaust pointed away from doors, windows and vents. Never in a garage, basement, shed or crawlspace, even with the door open.
- Carbon monoxide is odorless and can kill in minutes. Keep battery CO alarms working inside the home.
- Never backfeed a house by plugging a generator into a wall outlet or dryer receptacle. It can energize utility lines and kill a lineworker or a neighbor.
- Connecting to home wiring requires a transfer switch or a listed breaker interlock with a power inlet box, installed by a licensed electrician and permitted where your jurisdiction requires it.