Answer
Can the DuroMax XP13000EH run Danby DAR032B1SLM 3.2 cu ft compact refrigerator?
Runs
Runs. Running draw 150 W fits within 10,500 running watts. Startup watts were not published; 13,000 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.
Check priceOpens the manufacturer page. No affiliate link is set in links.json.
The comparison
| DuroMax XP13000EH | Danby DAR032B1SLM 3.2 cu ft compact refrigerator | |
|---|---|---|
| Running watts | 10,500 W | 150 W |
| Starting / surge watts | 13,000 W | Not published |
| Type | open-frame, Dual fuel (gasoline/propane) | Refrigeration |
| Published runtime | 8.5 hr at 50% load on gasoline, 6.5 hr at 50% on propane | |
| Sources | Generator source | Appliance source |
Questions
Can the DuroMax XP13000EH run Danby DAR032B1SLM 3.2 cu ft compact refrigerator?
Runs. Running draw 150 W fits within 10,500 running watts. Startup watts were not published; 13,000 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.
What watts were compared?
Generator: 10,500 running W and 13,000 starting W on gasoline. Appliance: 150 W running, startup not published.
How long will it run?
Fuel runtime depends on total load. Published runtime: 8.5 hr at 50% load on gasoline, 6.5 hr at 50% on propane.
Where did the numbers come from?
DuroMax spec sheet: gasoline 13000 starting / 10500 running; propane 12350 / 9975; 120/240V 30A twist-lock and 14-50R; 8.5 hr gas / 6.5 hr propane at 50%. Danby lists 115 V, 150 W, and 259 kWh/year. Average draw is 29.6 W. Duty cycle 0.197 is the annual average implied by those two figures. Startup watts are not published.
Safety first
- Run a generator outdoors only, at least 20 feet from the house, with the exhaust pointed away from doors, windows and vents. Never in a garage, basement, shed or crawlspace, even with the door open.
- Carbon monoxide is odorless and can kill in minutes. Keep battery CO alarms working inside the home.
- Never backfeed a house by plugging a generator into a wall outlet or dryer receptacle. It can energize utility lines and kill a lineworker or a neighbor.
- Connecting to home wiring requires a transfer switch or a listed breaker interlock with a power inlet box, installed by a licensed electrician and permitted where your jurisdiction requires it.