Answer

Can the Champion 2500W Ultralight Inverter (200951) run BLACK+DECKER BDM05C 5,000 Btu/h window air conditioner?

Runs

Runs. Running draw 347 W fits within 1,850 running watts. Startup watts were not published; 2,500 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.

Check priceOpens the manufacturer page. No affiliate link is set in links.json.

The comparison

Champion 2500W Ultralight Inverter (200951)BLACK+DECKER BDM05C 5,000 Btu/h window air conditioner
Running watts1,850 W347 W
Starting / surge watts2,500 WNot published
Typeinverter, GasolineCooling
Published runtime11.5 hr at 1/4 load
SourcesGenerator sourceAppliance source

Questions

Can the Champion 2500W Ultralight Inverter (200951) run BLACK+DECKER BDM05C 5,000 Btu/h window air conditioner?

Runs. Running draw 347 W fits within 1,850 running watts. Startup watts were not published; 2,500 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.

What watts were compared?

Generator: 1,850 running W and 2,500 starting W on gasoline. Appliance: 347 W running, startup not published.

How long will it run?

Fuel runtime depends on total load. Published runtime: 11.5 hr at 1/4 load.

Where did the numbers come from?

Champion operator's manual and sell sheet: 2500 starting / 1850 running, 79cc, 1.1 gal, 11.5 hr at 25% load, 39 lb. Outlet detail beyond 120V household outlets not verified. ENERGY STAR lists 5,000 Btu/h, CEER 14.4, 115 V, variable-speed compressor, and 260.4 kWh/year. Rated input is 5,000 ÷ 14.4 = 347.2 W. That matches the listed annual energy at the DOE room-AC assumption of 750 hours (347.2 × 750 ÷ 1,000 = 260.4). The 347.2 W figure is the draw while cooling at the rated condition, not a whole-year average. Startup watts are not published.

Safety first

More on the Champion 2500W Ultralight Inverter (200951) · More on this appliance