Answer

Can the Anker SOLIX C1000 run BLACK+DECKER BD12NWES 12,000 Btu/h window air conditioner?

Runs, surge risk

Runs, surge risk. Running draw 800 W is within 1,800 W continuous, but startup watts were not published. Willrun will not clear a compressor, pump, or tool start without that number. Estimated runtime: about 1.1 hr.

Check priceOpens the manufacturer page. No affiliate link is set in links.json.

The comparison

Anker SOLIX C1000BLACK+DECKER BD12NWES 12,000 Btu/h window air conditioner
Continuous output / running draw1,800 W800 W
Surge or peak2,400 WNot published
Resistive boost—Not eligible
Capacity / average draw1,056 Wh nameplate, 898 Wh usable800 W
Runtime1.1 hr
SourcesStation sourceAppliance source

Questions

Can the Anker SOLIX C1000 run BLACK+DECKER BD12NWES 12,000 Btu/h window air conditioner?

Runs, surge risk. Running draw 800 W is within 1,800 W continuous, but startup watts were not published. Willrun will not clear a compressor, pump, or tool start without that number. Estimated runtime: about 1.1 hr.

What watts were compared?

Station continuous output is 1,800 W. Motor surge used is 2,400 W. Appliance running draw is 800 W.

How was the runtime calculated?

1,056 Wh × 0.85 = 898 Wh usable, divided by 800 W average draw.

Where did the numbers come from?

Tech specs: 1,056 Wh, LiFePO4, 3,000 cycles to 80%, 1,800 W pure sine wave, 2,400 W AC surge, 6 AC outlets, 28.44 lb. The FAQ says SurgePad is for heat-generating devices when output exceeds the rated output; the 2,400 W figure is the published AC surge. ENERGY STAR lists 12,000 Btu/h, CEER 15, 115 V, variable-speed compressor, and 600 kWh/year. Rated input is 12,000 ÷ 15 = 800 W, which matches 600 kWh at 750 hours. Startup watts are not published.

More on the Anker SOLIX C1000 · More on this appliance