Answer

Can the Westinghouse WGen9500DF run ResMed AirSense 11, typical power from the user guide?

Runs, surge risk

Runs. Running draw 56 W fits within 9,500 running watts, and published startup 73 W fits within 12,500 starting watts. This is an open-frame generator with THD under 23%; for sensitive electronics or medical devices an inverter generator (under 3% THD) is the safer choice.

Check priceOpens the manufacturer page. No affiliate link is set in links.json.

The comparison

Westinghouse WGen9500DFResMed AirSense 11, typical power from the user guide
Running watts9,500 W56 W
Starting / surge watts12,500 W73 W
Typeopen-frame, Dual fuel (gasoline/propane)Medical
Published runtime12 hr at 25% load on gasoline, 7 hr at 50% on propane
SourcesGenerator sourceAppliance source

Questions

Can the Westinghouse WGen9500DF run ResMed AirSense 11, typical power from the user guide?

Runs. Running draw 56 W fits within 9,500 running watts, and published startup 73 W fits within 12,500 starting watts. This is an open-frame generator with THD under 23%; for sensitive electronics or medical devices an inverter generator (under 3% THD) is the safer choice.

What watts were compared?

Generator: 9,500 running W and 12,500 starting W on gasoline. Appliance: 56 W running, 73 W startup.

How long will it run?

Fuel runtime depends on total load. Published runtime: 12 hr at 25% load on gasoline, 7 hr at 50% on propane.

Where did the numbers come from?

Westinghouse spec table: gas 12500 peak / 9500 running; propane 11200 / 8500; L14-30R and 14-50R; 6.6 gal; 12 hr at 25% gas, 7 hr at 50% propane; 74 dBA; 211 lb; THD under 23%. Americas user guide, 65 W power supply section: typical power consumption 56.1 W (111.5 VA) and peak power consumption 73.2 W (137.6 VA). This is the published system figure, not the lower no-humidifier row on ResMed's separate therapy-power sheet.

Safety first

More on the Westinghouse WGen9500DF · More on this appliance