Answer
Can the Westinghouse iGen2200 run Danby DAR026A1BDD 2.6 cu ft compact refrigerator?
Runs
Runs. Running draw 90 W fits within 1,800 running watts. Startup watts were not published; 2,200 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.
Check priceOpens the manufacturer page. No affiliate link is set in links.json.
The comparison
| Westinghouse iGen2200 | Danby DAR026A1BDD 2.6 cu ft compact refrigerator | |
|---|---|---|
| Running watts | 1,800 W | 90 W |
| Starting / surge watts | 2,200 W | Not published |
| Type | inverter, Gasoline | Refrigeration |
| Published runtime | Up to 12 hr at 25% load | |
| Sources | Generator source | Appliance source |
Questions
Can the Westinghouse iGen2200 run Danby DAR026A1BDD 2.6 cu ft compact refrigerator?
Runs. Running draw 90 W fits within 1,800 running watts. Startup watts were not published; 2,200 starting watts is at least 3× the running draw, the common planning allowance for a compressor or pump start.
What watts were compared?
Generator: 1,800 running W and 2,200 starting W on gasoline. Appliance: 90 W running, startup not published.
How long will it run?
Fuel runtime depends on total load. Published runtime: Up to 12 hr at 25% load.
Where did the numbers come from?
Westinghouse product page: 2200 peak / 1800 running; 1.14 gal; up to 12 hr at 25%; 46.3 lb; duplex 5-20R and 2 USB. Older spec sheets list 10 hr at 25%. Danby lists 115 V, 90 W, and 253 kWh/year. Average draw is 28.9 W. Duty cycle 0.321 is the annual average implied by those two figures. Startup watts are not published.
Safety first
- Run a generator outdoors only, at least 20 feet from the house, with the exhaust pointed away from doors, windows and vents. Never in a garage, basement, shed or crawlspace, even with the door open.
- Carbon monoxide is odorless and can kill in minutes. Keep battery CO alarms working inside the home.
- Never backfeed a house by plugging a generator into a wall outlet or dryer receptacle. It can energize utility lines and kill a lineworker or a neighbor.
- Connecting to home wiring requires a transfer switch or a listed breaker interlock with a power inlet box, installed by a licensed electrician and permitted where your jurisdiction requires it.