Answer

Can the EcoFlow DELTA 2 run ResMed AirSense 11, typical power from the user guide?

Runs

Runs. Running draw 56.1 W is within 1,800 W continuous, and the published peak of 73.2 W is within 1,800 W. Estimated runtime: about 15.5 hr.

Check priceOpens the manufacturer page. No affiliate link is set in links.json.

The comparison

EcoFlow DELTA 2ResMed AirSense 11, typical power from the user guide
Continuous output / running draw1,800 W56.1 W
Surge or peakNot applied to motors73.2 W
Resistive boostX-Boost 2,200 WNot eligible
Capacity / average draw1,024 Wh nameplate, 870 Wh usable56.1 W
Runtime15.5 hr
SourcesStation sourceAppliance source

Questions

Can the EcoFlow DELTA 2 run ResMed AirSense 11, typical power from the user guide?

Runs. Running draw 56.1 W is within 1,800 W continuous, and the published peak of 73.2 W is within 1,800 W. Estimated runtime: about 15.5 hr.

What watts were compared?

Station continuous output is 1,800 W. No motor-surge rating is applied. Appliance running draw is 56.1 W. Published appliance peak is 73.2 W.

How was the runtime calculated?

1,024 Wh × 0.85 = 870 Wh usable, divided by 56.1 W average draw.

Where did the numbers come from?

US product page: about 1 kWh, 1,800 W output, X-Boost up to 2,200 W, LiFePO4, 3,000+ cycles. Weight, size, and the 4 AC outlets are from the EcoFlow DELTA 2 user manual. The manual line that pairs 1,800 W with a 2,700 W surge is printed next to 230 V, so that surge is not used for this 120 V entry. Americas user guide, 65 W power supply section: typical power consumption 56.1 W (111.5 VA) and peak power consumption 73.2 W (137.6 VA). This is the published system figure, not the lower no-humidifier row on ResMed's separate therapy-power sheet.

More on the EcoFlow DELTA 2 · More on this appliance