Answer

Can the Goal Zero Yeti 1000X run ResMed AirSense 10 AutoSet, no humidifier?

Runs

Runs. Draw is 7 W, within the 1,500 W continuous output. Estimated runtime on AC: about 38.5 hr, counting about 15 W of inverter draw.

Medical safety notice: Will It Run? gives general power estimates only, not medical advice. Power draw varies by model, settings, pressure, humidifier and altitude. Before relying on any battery, power station, inverter or generator for a medical device, confirm approved power sources with the device manufacturer and your doctor or equipment supplier, and test your setup before an emergency. Never change prescribed settings to extend battery life. If your therapy is life-sustaining, keep the backup your supplier provides, register with your utility's medical-needs program, and have an evacuation plan. Run generators outdoors only, at least 20 ft from windows and doors, because of carbon monoxide risk. In an emergency, call 911.

Check price on AmazonManufacturer pageAs an Amazon Associate we earn from qualifying purchases.

The comparison

Goal Zero Yeti 1000XResMed AirSense 10 AutoSet, no humidifier
Continuous output / running draw1,500 W7 W
Capacity / average draw997 Wh nameplate, 847 Wh usable7 W
Runtime on AC38.5 hr (7 W + about 15 W inverter draw)
Nights on AC (8 hr)4.8
On DC, best case5.0 days, 15.1 nights with the ResMed Air10 DC/DC converter 90W in the 12 V car port
SourcesStation sourceAppliance source

How AC runtime is figured: usable Wh (nameplate × 0.85) ÷ (CPAP watts + about 15 W). The 15 W is the inverter's own draw just to stay on: BLUETTI counts about 15 W of self-consumption in its AC180 runtime formula, and an owner test measured about 17.5 W idle on a DELTA 3 Plus. Larger stations can idle higher, so test your own setup before you rely on it. DC figures skip the inverter and are a best case. Method and DC converter limits: CPAP power station guide.

More on the Goal Zero Yeti 1000X · More on this machine · CPAP hub

Questions

Can the Goal Zero Yeti 1000X run ResMed AirSense 10 AutoSet, no humidifier?

Runs. Draw is 7 W, within the 1,500 W continuous output. Estimated runtime on AC: about 38.5 hr, counting about 15 W of inverter draw.

How was the runtime calculated?

On AC: 997 Wh × 0.85 = 847 Wh usable, divided by (7 W + about 15 W inverter draw) = 38.5 hr. On DC with the ResMed Air10 DC/DC converter 90W in the car port there is no inverter, so the best case is 847 Wh divided by 7 W = 5.0 days.

Where did the numbers come from?

Battery block: 997 Wh, NMC, 500 cycles to 80% at 1C, 31.68 lb. The ports section says 1,500 W and 3,500 W surge; a diagram label on the same page says 1,500 W and 3,000 W surge. The surge is omitted because the page disagrees with itself. Continuous 1,500 W is consistent. ResMed's therapy-device power table (ResMed Deutschland, Art.-Nr. 1018528/11) lists AirSense 10 AutoSet at 7 Wh during operation. Energy per hour equals average watts, so the average draw is 7 W. ResMed notes the values were measured in a lab and that a local meter can differ.